<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">33407</journal-id>
      <journal-title-group>
        <journal-title>Construction of Unique Buildings and Structures</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Строительство уникальных зданий и сооружений</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-6295</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">2</article-id>
      <article-id pub-id-type="doi">10.18720/CUBS.9.2</article-id>
      <title-group>
        <article-title>Calculation of air gap between the protective screen and the shell of reinforced concrete cooling tower</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Расчет воздушного зазора между защитным экраном и оболочкой железобетонной башенной градирни</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Belyaeva</surname>
            <given-names>Svetlana</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>sbelaeva@gmail.com</email>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0001-7011-8213</contrib-id>
          <contrib-id contrib-id-type="scopus">7801686579</contrib-id>
          <contrib-id contrib-id-type="researcherid">AAH-2547-2019</contrib-id>
          <name>
            <surname>Barabanshchikov</surname>
            <given-names>Iurii Germanovich</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
          <email>ugb@mail.ru</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Saint-Petersburg State Polytechnical University</aff>
      <aff id="aff2">Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russian Federation</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2013-04-16">
        <day>16</day>
        <month>04</month>
        <year>2013</year>
      </pub-date>
      <issue>4</issue>
      <issue-id pub-id-type="publisher-id">9</issue-id>
      <fpage>18</fpage>
      <lpage>28</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://unistroy.spbstu.ru/userfiles/files/2013/4(9)/2_belyaeva_bababanshchikov_09.pdf"/>
      <abstract xml:lang="en">
        <p>Article is devoted to a question of maintenance of effective protection of the cooling tower shell, using the screen with ventilated air gap. The purpose of the work is to determine the optimal parameters of the air gap by the calculation of heat and humidity and aerodynamic mode. In this article, there are calculations showing influence of temperature conditions and thickness of a ventilated air gap on warm, humidity and aerodynamic modes of its work.The thickness of the 140-160 mm of an air gap, provided on the heating air inlet gap, provides the ability to assimilate air moisture throughout the layer and to remove it in an atmosphere which prevents moisture condensation on cold surfaces of the concrete shell.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>cooling tower</kwd>
        <kwd>air ventilated gap</kwd>
        <kwd>vapourproof screen</kwd>
        <kwd>fiberglass screen</kwd>
        <kwd>warm moisture protection</kwd>
        <kwd>corrosive effect</kwd>
        <kwd>air gap</kwd>
      </kwd-group>