<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">33407</journal-id>
      <journal-title-group>
        <journal-title>Construction of Unique Buildings and Structures</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Строительство уникальных зданий и сооружений</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-6295</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">2</article-id>
      <article-id pub-id-type="doi">10.18720/CUBS.24.2</article-id>
      <title-group>
        <article-title>Construction of building in accordance with passive house standards</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Строительство здания, отвечающего стандартам пассивного дома</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Sovetnikov</surname>
            <given-names>Daniil</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>sovetnikov.daniil@gmail.com</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Peter the Great Saint Petersburg Polytechnic University</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2014-09-20">
        <day>20</day>
        <month>09</month>
        <year>2014</year>
      </pub-date>
      <issue>9</issue>
      <issue-id pub-id-type="publisher-id">24</issue-id>
      <fpage>11</fpage>
      <lpage>25</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://unistroy.spbstu.ru/userfiles/files/2014/9(24)/2_sovetnikov_24.pdf"/>
      <abstract xml:lang="en">
        <p>The article presents architectural and tree-dimensional planning solutions aimed at constructing a building structure in accordance withinternational standards of passive house. The article offers possible approaches to development architectural design of building and installation of technical equipment that must minimize expenses on energy consumption and increase its environmental friendliness. It is mentioned that foundational factors for the creation of energy-efficient building in compliance of heat balance are imperviousness of the building envelop, as high as possible level of cladding structure’s insulating as well as creating supply-extract system with utilization of energy consumption for heating and cooling supplyair.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>passive house</kwd>
        <kwd>low energy building</kwd>
        <kwd>energy efficiency</kwd>
        <kwd>insulation</kwd>
        <kwd>imperviousness</kwd>
      </kwd-group>