<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">33407</journal-id>
      <journal-title-group>
        <journal-title>Construction of Unique Buildings and Structures</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Строительство уникальных зданий и сооружений</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-6295</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">1</article-id>
      <article-id pub-id-type="doi">10.18720/CUBS.44.1</article-id>
      <title-group>
        <article-title>Corrosion of the steel thin-walled profiles in the enclosure structures</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Коррозия стальных тонкостенных профилей в ограждающих конструкциях</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>uznetsova</surname>
            <given-names>Valeria</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>kuznetsova_vy@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0001-7011-8213</contrib-id>
          <contrib-id contrib-id-type="scopus">7801686579</contrib-id>
          <contrib-id contrib-id-type="researcherid">AAH-2547-2019</contrib-id>
          <name>
            <surname>Barabanshchikov</surname>
            <given-names>Iurii Germanovich</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
          <email>ugb@mail.ru</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Peter the Great St. Petersburg Polytechnic University</aff>
      <aff id="aff2">Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russian Federation</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2016-05-22">
        <day>22</day>
        <month>05</month>
        <year>2016</year>
      </pub-date>
      <issue>5</issue>
      <issue-id pub-id-type="publisher-id">44</issue-id>
      <fpage>7</fpage>
      <lpage>18</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://unistroy.spbstu.ru/userfiles/files/2016/5(44)/1_barabanschikov_44.pdf"/>
      <abstract xml:lang="en">
        <p>Light steel thin-walled structures (LSTS), in particular, thermoprofiles are widely used in construction of building frames. According to the latest amendments in the documentary standards, zinc coated thermoprofiles without additional paint coating may be used as load-bearing structures only in non-aggressive conditions. Applying paint coating in addition to a zinc one entails extra expenses, while efficiency of this measure may not correspond to the costs. Resolving this issue requires special researches. The purpose of this article is to analyze conditions of corrosion processes and to develop methods of testing thin-walled steel products, taking into account the features of their service in walling.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>thin-walled galvanized steel profiles</kwd>
        <kwd>thermal profile</kwd>
        <kwd>corrosion</kwd>
        <kwd>procedure for corrosion testing</kwd>
        <kwd>protecting coating of paint</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>