<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">33407</journal-id>
      <journal-title-group>
        <journal-title>Construction of Unique Buildings and Structures</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Строительство уникальных зданий и сооружений</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2304-6295</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">2</article-id>
      <article-id pub-id-type="doi">10.18720/CUBS.81.2</article-id>
      <title-group>
        <article-title>Operation of horizontal ground heat exchanger in climatic conditions of the Krasnodar region</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Работа горизонтальной системы теплосбора в почвенно-климатических условиях Краснодарского края</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Chernyshev</surname>
            <given-names>Dmitry</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2019-05-10">
        <day>10</day>
        <month>05</month>
        <year>2019</year>
      </pub-date>
      <issue>6</issue>
      <issue-id pub-id-type="publisher-id">81</issue-id>
      <fpage>18</fpage>
      <lpage>27</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://unistroy.spbstu.ru/userfiles/files/86_2.pdf"/>
      <abstract xml:lang="en">
        <p>Modes of operation of horizontal ground heat exchanger of heat pump in Krasnodar region of Russia are investigated in this work. Ground temperature decreases from 3,6 °С to -1,6 °С in the area of the heat exchanger during the heating period due to increase of the heat removal of the heat exchanger from 25 W/m to 95 W/m, in this connection the coefficient of performance respectively decreases from 2,49 to 1,98. According to the results of mathematical modeling the temperature of the ground in the case of minimum heat removal reaches a temperature of undisturbed ground, the temperature of the ground in the case of maximum heat removal is reduced by 1 °C compared to the temperature of undisturbed ground.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>heat pump</kwd>
        <kwd>horizontal ground heat exchanger</kwd>
        <kwd>coefficient of performance</kwd>
        <kwd>heat-collector systems</kwd>
        <kwd>temperature distribution</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
