Latest issues

Articles from section "Heat supply, ventilation, air conditioning, gas supply and lighting"

Construction materials using auxetics for building protected structures

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2025
  • Issue: 3
  • 0
  • 58
  • Pages: 11703-11703

The contribution of solar radiation to the heat balance of a high-rise building in the summer period using the Lakhta Center as an example

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2025
  • Issue: 3
  • 0
  • 68
  • Pages: 11702-11702

Thermal irregularity of connection joints in modular and block-modular enclosing structures

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2025
  • Issue: 2
  • 3
  • 68
  • Pages: 11607-11607

Impact of slab edge zones on slab-on-grade heat losses

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2024
  • Issue: 4
  • 35
  • 1014
  • Pages: 11306-11306

Statistical and probabilistic analysis of the impact of heat gains from people on the cooling load

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2024
  • Issue: 4
  • 93
  • 1286
  • Pages: 11305-11305

Numerical model of the flow in the exhaust unit "opening – elbow"

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2023
  • Issue: 4
  • 32
  • 1158
  • Pages: 10926-10926

Ice formation of the building with a residential pitched roof and a cold attic space at the cold climate in the millionplus city

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2023
  • Issue: 1
  • 93
  • 2455
  • Pages: 10606-10606

Verification of the numerical model for the convective jet flow near the side hood

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2022
  • Issue: 7
  • 18
  • 1418
  • Pages: 10510-10510

Impact of Flue Gas Recirculation on the Efficiency of Hot-water Boilers

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2020
  • Issue: 8
  • 39
  • 3773
  • Pages: 9304-9304

Operational humidity of autoclaved aerated concrete in outer walls

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2018
  • Issue: 8
  • 81
  • 3748
  • Pages: 22-40

Designed thermophysical parameters of walls made of autoclaved aerated concrete blocks

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2018
  • Issue: 6
  • 55
  • 3576
  • Pages: 35-58

Air distribution in spectator ice arenas

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2015
  • Issue: 12
  • 43
  • 3214
  • Pages: 7-31

The economic efficiency of replacement of old heating pipes in St.Petersburg

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2015
  • Issue: 7
  • 13
  • 2915
  • Pages: 7-31

Preparatory stage of reconstruction of heating system in Peter the Great St. Petersburg Polytechnic University

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2015
  • Issue: 5
  • 7
  • 2756
  • Pages: 50-62

AVC-systemof the autonomous ventilation and air-conditioning

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2015
  • Issue: 5
  • 19
  • 2999
  • Pages: 7-17

Removing ice dams by using of а transient air hole

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2014
  • Issue: 5
  • 12
  • 2941
  • Pages: 54-64

Design and calculation of ventilation and air-conditioning systems. Review of Sotnikov A.G. new book

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2014
  • Issue: 2
  • 35
  • 3416
  • Pages: 39-43

Autonomous power installation with complex power effective electroproviding

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2013
  • Issue: 5
  • 7
  • 2904
  • Pages: 1-19

Calculation of air gap between the protective screen and the shell of reinforced concrete cooling tower

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2013
  • Issue: 4
  • 18
  • 3096
  • Pages: 18-28

The efficiency of chiller’s work

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2013
  • Issue: 1
  • 12
  • 2946
  • Pages: 55-65

Implantation of RMD 41-11-2012 Saint-Petersburg “Organization of heating systems in Saint-Petersburg”

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2013
  • Issue: 1
  • 13
  • 3029
  • Pages: 47-54

Gasification and plasma gasification as type of the thermal waste utilization

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2016
  • Issue: 12
  • 29
  • 3423
  • Pages: 84-92

Dispersion method of heating system flushing

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2016
  • Issue: 8
  • 9
  • 2836
  • Pages: 7-16

Assessment of moisture conditions of walls with façade’s thermoinsulation composite systems with external mortar layers

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2016
  • Issue: 6
  • 41
  • 3429
  • Pages: 34-54

The impact of unauthorized changes to heating system to heat supply of multistorey building

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2016
  • Issue: 4
  • 12
  • 2821
  • Pages: 46-57

Heat loss through the building unheated basement

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2016
  • Issue: 4
  • 22
  • 3136
  • Pages: 7-17

Influence of temperature and humidity conditions on building structures of basements

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2017
  • Issue: 3
  • 24
  • 3292
  • Pages: 18-34

The method and computation of air change required for attic rooms

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2017
  • Issue: 2
  • 55
  • 4503
  • Pages: 50-60

Floor heating based on amorphous metal tape

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2017
  • Issue: 11
  • 17
  • 3016
  • Pages: 15-24

Radiant heating and cooling systems based on capillary micro tubes

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2017
  • Issue: 9
  • 30
  • 3538
  • Pages: 31-41

Collisions of general utilities designing through the use of BIM-platforms

Heat supply, ventilation, air conditioning, gas supply and lighting
  • Year: 2018
  • Issue: 3
  • 42
  • 3517
  • Pages: 19-29